国语在线观看精品视频,99久热re在线精品99 6热视频,乱人伦中文视频在线,精品国产一区二区三区麻豆

  • <pre id="mfeih"></pre>
  • 跳過(guò)內(nèi)容
    北京鼎信優(yōu)威光子科技有限公司 Logo
    • 首頁(yè)
    • 資訊中心
    • 產(chǎn)品中心
    • 應(yīng)用中心
    • 資料下載
    • 聯(lián)系我們
    Simple-Tau時(shí)間相關(guān)單光子計(jì)數(shù)器整機(jī)dynadmin2020-05-14T09:48:49+08:00
    • 產(chǎn)品簡(jiǎn)介

    • 應(yīng)用領(lǐng)域

    • 產(chǎn)品資料

    • 產(chǎn)品簡(jiǎn)介

    緊湊型TCSPC時(shí)間相關(guān)單光子計(jì)數(shù)器整機(jī)

    • 基于筆記本電腦的帶有擴(kuò)展箱的TCSPC系統(tǒng)
    • 多達(dá)4個(gè)TCSPC或測(cè)量控制卡
    • 高度模塊化的系統(tǒng)
    • 用戶(hù)特定的硬件和軟件配置
    • 最小時(shí)間通道寬度低至407 fs
    • 電子IRF 3.3 ps FWHM
    • 高計(jì)數(shù)率
    • 高時(shí)序穩(wěn)定性
    • 包含檢測(cè)器控制模塊
    • 選擇您的TCSPC模塊
    • 應(yīng)用領(lǐng)域

    Applications

    • Recording the Kautsky Effect by Fluorescence Lifetime Detection
    • Timing Stability of TCSPC Experiments
    • bh FLIM Systems for Nikon C1 Scanners
    • Non-Descanned FLIM Systems for Olympus FV-1000 and FV-300 Multiphoton Microscopes
    • FLIM Systems for Zeiss LSM 710 Record Z Stacks
    • Recording Z Scans with the DCS-120 Confocal Scanning FLIM System
    • Tuneable Excitation FLIM with the LSM 710 Intune System
    • An 8-Channel Parallel Multispectral TCSPC FLIM System
    • Multiphoton Multiwavelength NDD FLIM with Zeiss LSM 710 NLO
    • Microsecond Decay FLIM: Combined Fluorescence and Phosphorescence Lifetime Imaging
    • Spatially Resolved Recording of Fluorescence-Lifetime Transients by Line- Scanning TCSPC
    • Combined Fluorescence and Phosphorescence Lifetime Imaging (FLIM / PLIM) with the Zeiss LSM 710 NLO Microscopes
    • DCS-120 Confocal Scanning System: FLIM with NIR Dyes
    • TCSPC at Wavelengths from 900 nm to 1700 nm
    • Multiphoton FLIM with the Leica HyD RLD Detectors
    • Multiphoton NDD FLIM at NIR Detection Wavelengths with the Zeiss LSM 7MP and OPO Excitation
    • FLIM and FCS by Pulse-Interleaved Excitation with the Zeiss LSM 710/780 Intune System
    • Mosaic FLIM: New Dimensions in Fluorescence Lifetime Imaging
    • Zeiss BiG-2 GaAsP Detector is Compatible with bh FLIM Systems
    • An AFM/NSOM System with Fluorescence Lifetime Imaging
    • NSOM FLIM with the Nanonics AFM/NSOM System
    • Implantable Fibre-Optical Fluorescence-Lifetime Detection System for in-vivo Applications
    • TCSPC Fibre-Probe System with an Exchangeable Tip
    • bh FLIM Systems Record Calcium Transients in Live Neurons
    • The PZ-FLIM-110 Piezo-Scanning FLIM System
    • 80 ps FHWM Instrument Response with ID230 InGaAs SPAD and SPC-150 TCSPC Module
    • World Record in TCSPC Time Resolution: Combination of bh SPC-150NX with SCONTEL NbN Detector yields 17.8 ps FWHM
    • bh – Abberior Combination Records STED FLIM at Megapixel Resolution
    • bh TCSPC Systems Record FLIM with Sutter MOM Microscopes
    • Wide-Field TCSPC FLIM with bh SPC-150N TCSPC System and Photek FGN 392-1000 Detector
    • TCSPC System Records FLIM of a Rotating Object
    • Metabolic Imaging with the DCS-120 Confocal FLIM System: Simultaneous FLIM of NAD(P)H and FAD

     

    • 產(chǎn)品資料

    The bh TCSPC Handbook
    8th edition, corrected and updated September 2019

    查 看

    Datasheets

    db-simpletau130-v04
    db-simpletau150-v04
    db-simpletau152-v04
    TCSPC時(shí)間相關(guān)單光子計(jì)數(shù)器
    Simple-Tau
    Simple-Tau II
    Power-Tau
    Max-Tau
    ? Copyright 2004 -????|???北京鼎信優(yōu)威光子科技有限公司 京ICP備05074267號(hào)-3
    Page load link
    返回頂部

    感谢您访问我们的网站,您可能还对以下资源感兴趣:

    国语在线观看精品视频,99久热re在线精品99 6热视频,乱人伦中文视频在线,精品国产一区二区三区麻豆
  • <noscript id="3w7r7"><input id="3w7r7"><div id="3w7r7"></div></input></noscript>
    • <bdo id="3w7r7"></bdo>